HumidityHighWarning #
Meaning #
The humidity in a room has exceeded 65% for the past 6 hours. This is a warning threshold indicating that humidity levels are becoming uncomfortable and may pose risks to electronics or equipment.
Impact #
Sustained high humidity can cause condensation on electronic equipment, promote mold growth, and create uncomfortable living conditions. Prolonged exposure above 65% can damage sensitive hardware.
Diagnosis #
Check the current humidity readings from all Shelly H&T sensors:
shellyht_humidity_percent
Identify which specific rooms or sensors are affected:
kubectl get pods -n iot -l app.kubernetes.io/name=shelly-ht-monitor -o yaml
Review the humidity trend over the past 24 hours to determine if this is a gradual increase or sudden spike.
Mitigation #
Open windows in the affected rooms to improve ventilation and reduce humidity levels.